CONNECTING THE WATER SUPPLY

CONNECTING THE WATER SUPPLY

On Ice Maker models BI 2015 and Combo 2075FF, install a 1/4 inch outside diameter copper water line (not supplied with unit) from the nearest COLD water pipe. When connecting the water supply, follow these guidelines:

Review the local plumbing codes before you install the unit.

In most instances, the cold water supply will come from the basement through a hole in the floor.

The water pressure should be between 15 and 150 psi.

Install a shut-off valve in the 1/4 inch outside diameter supply line.

Connect sufficient tubing to the unit to allow the unit to be moved for cleaning and servicing. However, make certain that the tubing is not pinched or damaged during installation.

U-Line recommends the use of copper tubing for installation.

1.Locate the compression fit- 2. Carefully bend the water supply

ting and ferrule packed in the

line into position and connect

unit. Slide

the compression

the line to the solenoid valve

fitting and ferrule over the

(see Figure 4). Avoid kinking

1/4

inch

outside diameter

the water supply line.

water supply line. Do not use

 

thread sealing compound or

 

tape. Using two wrenches,

 

tighten

the

compression fit-

WATER

ting

on

the

supply line (see

CONNECTION

Figure 3).

UL134

UL103

 

Figure 3

WATER 7 CONNECTION