6.2.2Steam Generator and Cooking Chamber
The steamer cavity and steam generator may be cleaned separately. When cleaning is scheduled, or if the SERVICE light is on, follow these simple de- liming instructions. REMEMBER: DON’T ALLOW
DE-LIMING AGENTS TO MIX WITH DE- GREASERS.
1.Set the timer to OFF position.
2.Turn off the steamer for five minutes.
3.Open the door and allow the cavity to cool.
4.After the cavity has cooled five minutes, make sure that the fan has stopped and remove the fan baffle partition by lifting it up and toward the center of the cavity.
5.Wipe out the cavity. Make sure the drain holes at the back of the cavity are clear of debris.
6.Hold down the CLEAN button while turning the steamer on. Continue holding it
until the CLEANING indicator light comes on. Then release the
button. After five minutes, the beeper will begin to beep rapidly. This is the signal to add 500 ml per cavity of Groen
equivalent as shown at right. Do not use any de- limer that contains chlorine.
7.Replace fan baffle partition and close door.
8.The cleaning cycle consists of a boiling clean stage, a soak stage, and a rinse stage. The full cycle takes about 50 minutes to complete.
9.WEAR PROTECTIVE GLOVES AND EYE PROTECTION FOR THIS
STEP. When the steamer beeper sounds, turn off the steamer and open the door. After the fan has stopped, remove the fan baffle partition and rinse it well in a sink. Wipe out the cavity
completely. If necessary, use a damp nylon pad.
10.Reinstall the fan baffle.
11.If the steamer will no longer be used, leave it off. Otherwise, wait 10 minutes and turn it back on. When the READY light comes on, the steamer is ready for operation.
6.2.3If the SERVICE light stays on:
1.Check that the water supply is on and that the supply hose is not kinked. With the problem corrected, turn the steamer off or 10 seconds and then
2.Repeat steam generator cleaning.
The process for