System Default Settings
Network
When using this unit on a network, go to SET UP section = [System] = [Network], and set the [Network] command to “ON”. Then go to SET UP section = [System] = [Network], and set the [DHCP/Manual] command either to use DHCP (Dynamic Host Configuration Protocol) or input the IP address used, together with
If “DHCP” is selected, confirm that a DHCP server in fact exists. If no server exists, a longer time will be required for the unit to boot to the idling condition when the power is turned on. When “DHCP” is
selected, the [IP Address] command will display the address automatically allocated to the recorder. Also, setting [Network] to “ON” makes it possible to check the MAC address of this unit.
Note:
Be very careful when setting IP address,
| UPS Support |
| Whenever the power to this unit is turned OFF, the |
| unit performs a shutdown operation. An unintentional |
| power interruption results in the power being |
| disconnected without the shutdown operation being |
| performed, thus resulting in potential malfunctions. In |
| order to avoid such malfunctions, the use of an |
| uninterrupted power supply (UPS) is recommended. |
| By going to SET UP section = [System] = [UPS |
| Setting] = [Model], you can select APC Smart- |
| UPS 700 or |
| Note: |
SET UP section = [System] = [Network] | |
| Also, if power is interrupted and the UPS operates, |
| the time before automatic shutdown is initiated can |
| be set to 30 seconds or 60 seconds (SET UP section |
| = [System] = [UPS Setting] = [Shutdown |
| Delay]). In this way, the shutdown operation will be |
| avoided if normal power is restored within the |
| selected time interval. |
SET UP section = [System] = [Network] = [DHCP/Manual] = [DHCP]
SET UP section = [System] = [Network] = [DHCP/Manual] = [Manual]
30
SET UP section = [System] = [UPS Setting]
Use the UPS products below, manufactured by
AMERICAN POWER CONVERSION CORP. (APC).
(Part Number: SU700NET)
Connection of other manufacturers’ UPS will not result in proper operation.