Valor Auto Companion Inc 739DVP, 739DVN Maintenance, Checks, General Servicing, Pilot flame

Models: 739DVP 739DVN

1 31
Download 31 pages 52.33 Kb
Page 27
Image 27
20.4 Checks

Maintenance

20.4 Checks

Performance of LPG appliances may be affected by the quality of commercial gas supplied in your area.

1.A periodic check of the pilot and burner flames should be made. Check after the fire has been on for at least 30 minutes. The pilot flame must cover the tip of the thermocouple probe. The main burner flame pattern will vary from appliance to appliance depending on the type of installation and climatic conditions.

Pilot flame

Flame picture

2.The appliance area must always be kept clear and free from combustible materials, gasoline and other flammable vapors and liquids.

3.Inspect the vent terminal outdoors regularly to make sure that dirt, snow, insects, leaves and trees or other object do not obstruct it.

4.Examine the whole vent system regularly using a qualified agency. We recommend an annual inspection.

20.5 General Servicing

If your appliance requires any servicing, contact your supplier quoting the model number. It will be helpful if the appliance’s serial number can also be quoted. The serial number is on the rating plate, which is located under the firebox, and is accessible by opening the bottom access panel of the front.

The repair parts are shown in the separate repair parts leaflet. Please always quote the part number and description when requesting a spare part.

27

Page 27
Image 27
Valor Auto Companion Inc 739DVP, 739DVN owner manual Maintenance, Checks, General Servicing, Pilot flame