Vanguard VE32LB, VE36LH, VE36LBH, VE32LH Maintenance, Replacing Light Bulbs, Maintaining Motors

Models: VE36L VE32LBH VE32L VE32LH VE36LH VE32LB VE36LBH VE36LB

1 28
Download 28 pages 11.27 Kb
Page 15
Image 15
Maintenance

Maintenance

Replacing Light Bulbs WARNING: Disconnect power before attempting any maintenance or cleaning to re- duce the risk of fire, electrical shock or personal injury.

Maintaining Motors WARNING: Any electrical repairs or rewiring of this unit should be carried out by a licensed electrician in accor- dance with national and local codes.

Removing/Replacing Control Door WARNING: Do not exceed 60 watts per bulb when replac- ing bulbs. Use of higher-rated bulbs may result in a fire, caus- ing property damage, personal injury, or loss of life.

Replacing Light Bulbs

There are (3) colored lamps rated at 120V, 60 Watts, for use in a medium sized socket. These bulbs are located under the log bed and can be replaced as follows:

1.If you are unsure which bulb needs replacement, defective bulbs may be visually located as any of 3 bulbs colored - Red, Yellow and Orange starting from the left (see Figure 12, page 7). Defective bulbs can be replaced individually or for convenience you may want to replace all bulbs at the same time; even if only one is defective.

2.Disconnect power to unit at main breaker or fuse panel.

3.Lift log bed off hearth base to gain access to lamp fixtures. Log bed is attached with contact magnets only.

4.Remove each defective bulb from its socket and replace with appropriate color and size bulb.

Note: Be careful not to tear or damage reflec- tive ribbons. If they have come loose, they can be easily reattached or replaced at the support brackets. See Replacing Reflective Ribbons, page 21.

5.Return power to circuit and turn main power switch and lamp power on to check opera- tion of bulbs before replacing log set.

6.If all bulbs are working properly, replace the log bed over the center opening in between rear screen and front grate.

Manual background CAUTION: Make sure power is turned off at supply prior to disassembling this unit.

Maintaining Motors

Motors used on fan and heater assembly are permanently lubricated and do not require lubrication. Annual cleaning and/or vacuuming around heater and fan unit is recommended.

Removing/Replacing Control Door

The upper control door may be removed for service or replacement when necessary:

1.Open upper control door (see Figure 13, page 7).

2.Remove 4 Phillips screws from deflector shield. Angle deflector shield out of open- ing (see Figure 29).

3.Remove 4 Phillips screws from magnet assemblies.

4.Lift up on inner control door and push in each end until pivot pins are free of notches located on each side of access opening (see Figure 29).

Deflector

Control

Door

Shield

Magnet

 

Push

Assembly

Angle

Door Up

and

Door and

Back

Slide

 

Out of

 

Housing.

Figure 29 - Removing/Replacing Control

Door

115121-01B

www.desatech.com

15

Page 15
Image 15
Vanguard VE32LB, VE36LH, VE36LB Maintenance, Replacing Light Bulbs, Maintaining Motors, Removing/Replacing Control Door