Vanguard VE36LBH, VE36LH manual Maintenance, Continued, Replacing Lamp Fixtures, Imaging Unit, page

Models: VE36L VE32LBH VE32L VE32LH VE36LH VE32LB VE36LBH VE36LB

1 28
Download 28 pages 11.27 Kb
Page 20
Image 20
Replacing Lamp Fixtures

MAINTENANCE

Continued

Replacing Lamp Fixtures

Lamp fixtures may be replaced as follows:

1.Turn off all power to fireplace at circuit breaker or fuse.

2.Locate any of 3 defective lamp fixtures and trace wiring to crimp connectors in harness and disconnect.

3.Remove 2 crimp connectors in harness and disconnect white and black wires on defective fixture. See Wiring Diagram, Fig- ure 28 on page 14, for proper locations.

4.Remove 2 Phillips screws at base of defective fixture (see Figure 39).

5.Remove old fixture and mount new fixture with 2 Phillips screws removed prior.

6.Twist bare ends of white and black wires to corresponding wires in main harness and secure them with 2 crimp connectors provided.

Note: There should be no exposed bare wire at any connection. Wiring should be secured with wire ties, as short as possible, and kept away from fan blades. If additional parts are required, see Replacement Parts, on page 22.

7.Replace each light bulb with proper color, (see Replacing Light Bulbs, page 14).

8.Restore power and check lamp circuit op- eration before reassembling imaging unit.

9.Reassemble imager. See Accessing

Imaging Unit, page 16.

Imaging Unit, page 16. Make sure power is turned off at supply prior to disassembling this unit.

IMPORTANT: Be sure to inspect components and wiring for damage before connecting power to unit. If any components are found damaged, contact an authorized dealer for original DESA replacement part(s) or call

DESA at 1-866-872-6040 for referral.

Upper Hanger

Bracket

Hanger

Manual background Screws

Screws and

Washers

Reflective Manual background

Ribbon

Bottom Hanger Manual backgroundManual background

Bracket

Screws

Lamp

Fixture Manual background

Crimp Manual background

Connectors

Reflective

Ribbon

Base Manual background

Cover

Ribbon Support Bracket

Cellophane

Tape

Figure 39 - Replacing Fixtures (Shown without FIrebox for Clarity)