INSTALLATION

Continued

INSTALLATION CLEARANCES

Minimum clearances to combustible construc- tion are:

• Top, Back and Sides of Recessed Cabinet . . . . . . . . . . . 0" Min.

Drywall to Sides of Front Face . . 0" Min.

Framing at Nailing Flanges. . . .0" Min.

Ceiling to Opening. . . . . . .36" Min.

Floor

.

.

. 0" Min.

Front

.

.

.36" Min.

Perpendicular Side Wall . .

.

.

10" Min.

Mantel Clearances

For mantel clearances see Figures 3 and 4.

 

 

 

Facing Material May

 

 

 

Be Noncombustible

 

 

12" Ref.

Wall Treatments or

 

 

Combustible Wood

 

 

 

 

 

10 1/2"

Combustible Wood

 

 

 

 

 

4 1/2"

Mantels and Trims

 

30°

1 1/2"

May Extend Above

 

 

Profile Shown when

 

 

 

Maintained within 30°

 

 

 

Parameter Shown

16

5/8"

1 3/4"

Framed

 

Material

Ref.

 

 

 

133/4"

Top of Cabinet

10 1/2" Min.

9 5/8" Ref.

Note: All Mantel Clearances are Measured from Top of Fireplace Opening

Figure 3 - Mantel Clearances

 

Edge of Firebox

Top View of Fireplace

Opening

 

3"

 

Safe Zone

Combustible

30°

5"

1 3/4" Max.

MaterialMust

 

 

 

Not Overlap

 

Minimum 10" from

Front Face

 

 

 

Perpendicular Side Wall

 

Figure 4 - Mantel Side Clearances

CABINET MANTEL INSTALLATION

This fireplace may be installed using a cabi- net mantel accessory against any wall with an available 120 volt grounded outlet. The cabinet mantel accessory includes both a base and a trim kit.

IMPORTANT: To install perimeter trim kit, you must install shoulder screws before installing fireplace into cabinet mantel. See instructions included with trim kit. When installing a man- tel accessory, you must follow all clearance instructions (see Installation Clearances, column 1).

1.Assemble cabinet mantel accessory and trim kit by following assembly instructions included with each kit.

2.Place hearth base close to wall at desired location. Leave enough room to get be- hind unit and attach mantel to base once fireplace and mantel has been placed.

When possible, location should be within 3" of power outlet so mantel will cover outlet with installed (see Figure 5 and Figure 6, page 5).

3.Plug power cord into outlet.

Note: Power cord comes preattached to right side of cabinet. If it is necessary to relocate cord to left side you must remove power cord assembly (see Figure 7). Fol- low instructions to relocate junction box (see Electrical Installation, on page 6). Power cord must be properly mounted and reconnected at junction box.

4.Slide assembled mantel over fireplace un- til nailing flanges are centered into opening flush against rear cabinet facing.

Cabinet

Mantel

Power

Cord

Electric

Outlet

Perimeter

Trim

Accessory

Figure 5 - Installing Flush Cabinet Mantel

www.desatech.com115121-01B

Page 4
Image 4
Vanguard VE36LBH, VE36LH, VE32L Installation Clearances, Cabinet Mantel Installation, For mantel clearances see Figures 3