INSTALLATION
Continued
INSTALLATION CLEARANCES
Minimum clearances to combustible construc- tion are:
• Top, Back and Sides of Recessed Cabinet . . . . . . . . . . . 0" Min.
•Drywall to Sides of Front Face . . 0" Min.
•Framing at Nailing Flanges. . . .0" Min.
•Ceiling to Opening. . . . . . .36" Min.
• | Floor | . | . | . 0" Min. |
• | Front | . | . | .36" Min. |
• | Perpendicular Side Wall . . | . | . | 10" Min. |
Mantel Clearances
For mantel clearances see Figures 3 and 4.
|
|
| Facing Material May |
|
|
| Be Noncombustible |
|
| 12" Ref. | Wall Treatments or |
|
| Combustible Wood | |
|
|
| |
|
| 10 1/2" | Combustible Wood |
|
|
| |
|
| 4 1/2" | Mantels and Trims |
| 30° | 1 1/2" | May Extend Above |
|
| Profile Shown when | |
|
|
| Maintained within 30° |
|
|
| Parameter Shown |
16 | 5/8" | 1 3/4" | Framed |
| Material | ||
Ref. |
| ||
|
|
133/4"
Top of Cabinet
10 1/2" Min. | 9 5/8" Ref. |
Note: All Mantel Clearances are Measured from Top of Fireplace Opening
Figure 3 - Mantel Clearances
| Edge of Firebox |
Top View of Fireplace | Opening |
| 3" |
| Safe Zone | Combustible | |
30° | 5" | ||
1 3/4" Max. | MaterialMust | ||
| |||
|
| Not Overlap | |
| Minimum 10" from | Front Face | |
|
| ||
| Perpendicular Side Wall |
|
Figure 4 - Mantel Side Clearances
CABINET MANTEL INSTALLATION
This fireplace may be installed using a cabi- net mantel accessory against any wall with an available 120 volt grounded outlet. The cabinet mantel accessory includes both a base and a trim kit.
IMPORTANT: To install perimeter trim kit, you must install shoulder screws before installing fireplace into cabinet mantel. See instructions included with trim kit. When installing a man- tel accessory, you must follow all clearance instructions (see Installation Clearances, column 1).
1.Assemble cabinet mantel accessory and trim kit by following assembly instructions included with each kit.
2.Place hearth base close to wall at desired location. Leave enough room to get be- hind unit and attach mantel to base once fireplace and mantel has been placed.
When possible, location should be within 3" of power outlet so mantel will cover outlet with installed (see Figure 5 and Figure 6, page 5).
3.Plug power cord into outlet.
Note: Power cord comes preattached to right side of cabinet. If it is necessary to relocate cord to left side you must remove power cord assembly (see Figure 7). Fol- low instructions to relocate junction box (see Electrical Installation, on page 6). Power cord must be properly mounted and reconnected at junction box.
4.Slide assembled mantel over fireplace un- til nailing flanges are centered into opening flush against rear cabinet facing.
Cabinet
Mantel
Power
Cord
Electric
Outlet
Perimeter
Trim
Accessory
Figure 5 - Installing Flush Cabinet Mantel
www.desatech.com115121-01B