SPECIFICATIONS

SPECIFICATIONS

WIRING

DIAGRAM

Btu (Variable)

Type Gas

Ignition

Pressure Manifold

Inlet Gas

Pressure (in. of water)

Maximum

Minimum*

*For purpose of input adjustment Shipping Weight

On

 

Off

Switch

Auto

 

Thermopile

18" Variable

24" Variable

30" Variable

16,000/26,000

20,000/33,000

21,500/36,000

Propane Only

Propane Only

Propane Only

Piezo

Piezo

Piezo

7.9" W.C.

7.9" W.C.

7.9" W.C.

14"

14"

14"

11"

11"

11"

32 lbs.

34 lbs.

36 lbs.

White

Red

TPTH TH

Gas Control

TPTH TP

Red

White

TECHNICAL

SERVICE

SERVICE HINTS

26

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).

When gas pressure is too low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

propane (LP) gas supply may be low

When gas quality is bad

pilot will not stay lit

burners will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane (LP) gas supplier.