TO TURN OFF GAS TO APPLIANCE

20

OPERATING HEATER

Continued

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 8.

Pilot Burner

Ignitor Electrode

Figure 22 - Pilot

9.Slightly push in and turn control knob counterclockwise THERMOSTAT CONTROL OPERATION to the ON position.

10.Wait one minute and switch remote selector switch to the ON position to light burner.

11.Set flame adjustment knob to any level between HI and LO.

MANUAL LIGHTING PROCEDURE CAUTION

Do not try to adjust heating levels by using the manual shutoff valve.

Manual background WARNING

Make sure the remote selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on automatically with remote selector switch in the ON position.

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise Manual background to the OFF position.

2.Set remote selector switch in the OFF position to prevent draining battery.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

Turn control knob clockwise Manual background to the PILOT position.

Use remote control manual OFF button.

Set remote selector switch in the OFF position.

THERMOSTAT CONTROL OPERATION

The thermostat control setting on the remote control unit can be set to any comfort level between HI and LO. The Burners will turn on and off automatically to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

MANUAL LIGHTING PROCEDURE

1.Follow steps 1 through 6 under Lighting Instructions, page 19.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 9, above.