Nortel Networks 1000E warranty Checking MG 1000T trunking functionality

Models: 1000E

1 490
Download 490 pages 31.09 Kb
Page 287
Image 287

Verifying the network Page 287 of 488

Checking MG 1000T trunking functionality

To check trunking on the MG 1000T follow Procedure 73 on page 287.

Procedure 73

Checking the status of the MG 1000T trunks

1Install an i2050 on MG 1000T core. Refer to IP Line: Description, Installation, and Operation (553-3001-365) for additional information.

2Establish a call from the i2050 to a telephone on CS 1000E using CDP number.

3Establish a call from i2050 to the PSTN.

4Establish a call from the i2050 to a telephone on the CS 1000E through the PSTN using <local AC code> <NXX>, for example 9-967-5555.

End of Procedure

Establish CS 1000E DID calls from MG 1000T

To check CS 1000E DID calls from MG 1000T follow procedure

To terminate incoming DID calls the number of digits picked up at the terminating node for call termination, from the Called Number of the message is based on the length of LDN value. LDN0 is considered for this by default. Therefore to ensure that all the five digits of the DN are considered for call termination LDN0 should have a five digit number.

Procedure 74

Check CS 1000E DID calls from MG 1000T

1Establish a Listed Directory Number in LD 15.

2Ensure that all the digits of the DN are considered for call termination, LDN0 should be a number whose length is equal to the maximum length DN on the Node.

For example, if DNs are five digits, then LDN0 could be configured as 55555.

3Establish a DID call.

End of Procedure