Nortel Networks 1000E warranty Installing an alarm using an alarm port assigned in LD, Type CDB

Models: 1000E

1 490
Download 490 pages 31.09 Kb
Page 456
Image 456

Page 456 of 488 Installing and cross-connecting an external alarm from a PFTU

Installing an alarm using an alarm port assigned in LD 15

The system can be equipped with an alarm port that is assigned in software. Connect an analog line to an analog (500/250-type) telephone or another similar type of ringing or alerting device.

Follow Procedure 118 to install an alarm using an alarm port assigned in

LD 15.

Procedure 118

Installing an alarm using an alarm port assigned in LD 15

1Install an analog (500/2500-type) line as described in “Installing and configuring IP Phones” on page 395.

2Connect an analog (500/2500-type) telephone, or another similar alerting device used as an alarm, to the line.

3Use LD 15 to assign an alarm port, (see Table 60).

Note: If the DN assigned to the alarm is accidentally called, the alarm activates. To avoid false alarms, make sure the DN is not already assigned.

Table 60

LD 15 – Assign an alarm port.

Prompt

Response

Comment

 

 

 

 

 

REQ

CHG

Change existing data

TYPE

CDB

Customer Data Block

CUST

xx

Customer Number as defined in LD 15

...

 

 

 

 

 

 

ALDN

x...x

Alarm Directory Number

 

 

 

 

 

 

 

 

 

 

 

End of Procedure

 

 

 

 

 

 

 

553-3041-210 Standard 4.00 September 2007

Page 456