Page 140 of 488 Installing software on the CS 1000E

4Print the customer data block in LD 21.

LD 21

Load program

REQ

PRT

TYPE

CDB

CUST

xx

****

Exit program

Reconfigure I/O ports and call registers

Procedure 24

Reconfiguring I/O ports and call registers

1Evaluate the number of call registers and 500 telephone buffers that are configured for the system (suggested minimum values are 4500 and 1000 respectively). If changes are required, reconfigure the values in LD 17:

LD 17

Load program

500B 1000 Use 1000 as a minimum value

NCR 20000 Use 20000 as a minimum value

****Exit program

2Print the Configuration Record to confirm the changes made in Step 1:

LD 22

Load program

REQ PRT Set the print option

TYPE CFN Print the configuration

****Exit program

End of Procedure

Procedure 25

Switching call processing to the Call Server

1Plug the Call Server port labeled Lan 1 into the ELAN subnet.

2Initialize (using the init button) the CP PIV card in the Core.

553-3041-210 Standard 4.00 September 2007

Page 140
Image 140