Installing and cross-connecting a Power Fail Transfer Unit Page 447 of 488

Installing and connecting a third-party PFTU

Follow the equipment manufacturer’s instructions for installing the PFTU. Use the information in Table 57 to connect a third-party PFTU.

Table 57

PFTU control lead signals

 

Lead State

 

 

 

NTAK1104 AUX

When PFTU is in

When PFTU is in

cable lead

non-transferred state

transferred state

 

 

 

BRTN

GROUND

GROUND

 

 

 

BRTN

GROUND

GROUND

 

 

 

-48V AUX

-48V DC (250 mA max.)

-48V DC (250 mA max.)

 

 

 

PFTS

OPEN

GROUND

 

 

 

Note 1: Refer to Figure 152 on page 444 to see where the Auxiliary cable connects to the CS 1000E system.

Note 2: If power is removed from the QUA6, a transfer of the PFTU can occur.

Communication Server 1000E Installation and Configuration

Page 447
Image 447
Nortel Networks 1000E Installing and connecting a third-party Pftu, Pftu control lead signals Lead State, Brtn Ground