Installing and configuring the Signaling Server software

Page 193 of 488

 

 

Figure 73

IP Telephony parameter configuration

CS 1000 Signaling Server Software Install Tool (sse-x.xx.xx)

=====================================================================

You have entered the following parameters for this Leader Signaling Server:

Node ID

 

:

276

Hostname

 

: SS_Node276_Ldr

ELAN IP

 

: 192.168.20.100

ELAN subnet mask: 255.255.255.0

ELAN gateway IP : 192.168.10.1

TLAN IP

 

: 192.168.20.20

TLAN subnet mask: 255.255.255.0

TLAN gateway IP : 192.168.20.1

Node IP

 

: 192.168.20.100

Call Server IP

: 192.168.10.10

NRS configuration: Alternate GK + SIP

Primary

NRS IP

 

: 192.168.20.10

Alternate NRS IP : 192.168.20.24

 

Please enter:

<CR> ->

<y> - Yes, these parameters are correct.

 

<n> - No, these parameters are not correct.

Enter Choice>

The system echoes the ELAN network interface MAC address.

For future reference, the ELAN MAC address is: “00:02:b3:c5:5l:c6”.

This address is on the face of the Signaling Server, on the right side when the bezel door is open.

Note: The ELAN network interface MAC address must be configured in the Element Manager node configuration web page.

16To complete the installation, the Installation Status Summary screen appears as shown in Figure 74 on page 194.