3Test the System Utility card:

LD 135

Load program

STAT SUTL

Get the status of the System Utility card

TEST SUTL

Test the System Utility card

4Test system redundancy and media devices:

LD 137

Load program

TEST RDUN

Test redundancy

DATA RDUN

Test database integrity

STAT FMD

Status of one or both Fixed Media Devices

 

(FMD)

STAT RMD

Status of one or both Removable Media Devices

 

(RMD)

****Exit the program

5Clear the display and minor alarms on both Call Servers:

LD 135

Load program

CDSP

Clear the displays on the Call Servers

CMAJ

Clear major alarms

CMIN ALL

Clear minor alarms

6Check dial tone.