Page 158 of 488 Connecting MG 1000T system components

Procedure 34

Connecting the MG 1000T Core to an MG 1000T Expansion

1Choose one of the following:

a.For point-to-point 100BaseT connectivity, go to step 2.

b.For 100BaseT connectivity over a distributed Campus Data Network, go to step 9 on page 159.

2For the MG 1000T Core connect port 1 of the SSC 100BaseT daughterboard #1 to the bulkhead connector #1 shown in Figure 39 on page 159.

Note 1: If the SSC cable is connected to bulkhead Port 1, then use Port 1 on the back of the Media Gateway. If the SSC cable is connected to bulkhead Port 2, then use Port 2 on the back of the Media Gateway.

Note 2: Port 1 on the MG 1000T Core must go to MG 1000T Expansion 1, Port 2 to MG 1000T Expansion 2, and so on.

3Connect the 100BaseT RJ-45 connector 1 on the back of the Media Gateway to the identical connector on the first Survivable MG 1000T Expansion, shown in Figure 40 on page 160.

Use the supplied NTTK34AA two-meter UTP CAT5 RJ-45 cross-over cable to connect the MG 1000T Core and the Survivable MG 1000T Expansion.

4Connect port 1 of the MG 1000T Expansion 100BaseT daughterboard #2 to the bulkhead connector #1, as shown in Figure 39 on page 159.

5For MG 1000T Expansion 2, connect port 2 of the MG 1000T Core 100BaseT daughterboard #1 to the bulkhead connector #2, shown in Figure 39 on page 159

6Connect the 100BaseT RJ-45 connector 2 on the back of the Media Gateway to the 100BaseT RJ-45 connector 1 on the second MG 1000T Expansion, shown in Figure 40 on page 160.

7Connect port 1 of the MG 1000T Expansion 100BaseT daughterboard #2 to the bulkhead connector #1, as shown in Figure 39 on page 159

553-3041-210 Standard 4.00 September 2007

Page 158
Image 158
Nortel Networks 1000E warranty 158 of 488 Connecting MG 1000T system components