Page 214 of 488 Configuring the CS 1000E Call Server

LD 97 – Configuring the MG 1000E ports (Part 2 of 2)

Prompt

Response

Comment

 

 

 

ZONE0

0-255

First MG 1000E zone number

VXTC0

l x

First MG 1000E Virtual conference circuit starting loop

 

 

number. Two consecutive VXCTs are assigned.

 

 

The VXCTs must be previously configured in LD 17.

 

 

Where:

 

 

l = 0-252

 

 

x = 0 means 1 TDS loop only.

 

 

x = 1 means 1 TDS loop and 1 conference loop.

 

 

x = 2 means 2 TDS loops and 2 conference loops.

 

 

x = 3 means 2 TDS loops and 3 conference loops.

 

 

x = 4 means 2 TDS loops and 4 conference loops.

 

 

Precede with X to remove.

IPR1

xx.xx.xx.xx

IP address of second MG 1000E cabinet uplink IP address;

 

 

<cr> to skip to IPR2 when configuring new superloop.

ZONE1

0-255

Second MG 1000E zone number

VXCT1

l x

Second MG 1000E Virtual conference circuit starting loop

 

 

number. Two consecutive VXCTs are assigned.

 

 

The VXCTs must be previously configured in LD 17.

 

 

Where:

 

 

l = 0-252

 

 

x = 0 means 1 TDS loop only.

 

 

x = 1 means 1 TDS loop and 1 conference loop.

 

 

x = 2 means 2 TDS loops and 2 conference loops.

 

 

x = 3 means 2 TDS loops and 3 conference loops.

 

 

x = 4 means 2 TDS loops and 4 conference loops.

 

 

Precede with X to remove.

 

 

 

Configuring Digitone Receivers

Digitone Receivers must be configured in each MG 1000E if any analog terminals or trunks are equipped. The loop of the Digitone Receivers is the

553-3041-210 Standard 4.00 September 2007

Page 214
Image 214
Nortel Networks 1000E warranty Configuring Digitone Receivers