Page 450 of 488 Installing and cross-connecting a Power Fail Transfer Unit

Procedure 116

Connecting an analog (500/2500-type) telephone to a PFTU

1Locate the telephone terminations on the cross-connect terminal.

2Connect one end of the cross-connect wire to the leads of the telephone.

3Locate the PFTU connections (unit PFTU 1 through PFTU 5) assigned to this telephone at the cross-connect terminal. See Table 58 on page 450.

4Connect the other end of the cross-connect wire to the pair assigned to the telephone on the PFTU.

5Connect a second cross-connect wire to the pair assigned to the Line card on the PFTU.

6Locate the Line card terminations on the cross-connect terminal.

7Connect the other end of the cross-connect wire to the assigned TN terminal block.

Table 58

Power Fail Transfer Unit connections (Part 1 of 3)

QUA6 J1 Cable

Function

Pair

Color

Connects to:

 

 

 

 

 

5T

W-S

Telephone

 

5R

S-W

 

 

 

 

 

 

6T

R-BL

Telephone Line card

 

6R

BL-R

 

PFT 1

 

 

 

7T

R-O

Central Office Trunk

 

 

7R

O-R

 

 

 

 

 

 

8T

R-G

Trunk Line card

 

8R

G-R

 

 

 

 

 

553-3041-210 Standard 4.00 September 2007