Connecting MG 1000T system components Page 159 of 488

8MG 1000T Expansion 3 and 4 network cables (NTDU0609) must be routed from the 100 BaseT daughterboard through the cable slot on the side of the MG 1000T Core with one ferrite on the inside of the Media Gateway and the second ferrite external to the Media Gateway as shown in Figure 39 on page 159. Connect to MG 1000T Expansion 3 and 4 using the 100BaseT RJ-45 connector 1 on the back of each Media Gateway.

Note 3: The NTDU0609 crossover cables are connected directly to the MG 1000T Core 100BaseT Daughterboards for MG 1000T Expansion 3 and 4.

Note 4: The required NTDU0609 crossover cables are contained in the NTDU19BA Cable Kit.

Figure 39

MG 1000T SLAN subnet cables

Cable slot for NTDU0609 cables to MG 1000T Expansion 3 and 4

100BaseT cable to MG 1000T #1 MG 1000T #2 MG 1000T #3 MG 1000T #4

9Connect the MG 1000T Core ports, shown in Figure 40 on page 160 to the data network switch using a CAT5 patch cable.

Note: A customer supplied standard CAT5 cable is required.

Communication Server 1000E Installation and Configuration

Page 159
Image 159