System components Page 47 of 488

Table 2

Signaling Server profile (Part 2 of 2)

Property

Description

 

 

Connectors

• The DB-9 serial port, the CD-ROM and floppy

(front)

drives are located on the unit’s faceplate.

 

• The DB-9 serial port can support a login session

 

for Command Line Interface (CLI) management.

 

• See Figure 4 on page 48.

 

 

Connectors

• The TLAN network interface (P2) connects the

(rear)

unit to a TLAN network interface on a Layer 2

 

Switch.

 

• The ELAN network interface (P1) connects the

 

unit to an ELAN network interface on a Layer 2

 

Switch.

 

• The DB-9 serial port can support a login session

 

for Command Line Interface (CLI) management.

 

• There are three ports not used for any CS 1000E

 

system function. Do not plug any device into these

 

ports.

 

• See Figure 5 on page 49.

 

 

CAUTION — Service Interruption

Do not connect maintenance terminals or modems to the faceplate and I/O panel DB-9 male serial maintenance port at the same time.

For detailed information about the Signaling Server, refer to Signaling

Server: Installation and Configuration (553-3001-212).