Page 380 of 488 Configuring an IP telephony node

The Follower Signaling Server attempts to FTP the BOOTP.TAB file from the node master (Leader Signaling Server).

Note: Since the Follower cannot obtain the system login and password, the FTP fails (for first-time Follower Signaling Server installation only). It does not have the current CONFIG.INI file that contains the CS 1000E IP address. Subsequent FTPs succeed.

6Transfer the node files again, so that the Follower Signaling Server obtains a copy of CONFIG.INI.

7Reboot the Follower Signaling Server so that all its applications can start based on the new CONFIG.INI file.

The Signaling Server uses BootP to obtain its network data, and it then FTPs the BOOTP.TAB file from the node master (Leader Signaling Server).

End of Procedure

Performing a datadump

Follow Procedure 97 to perform a datadump using Element Manager. This procedure is an alternative to using CLI to perform a datadump. The datadump backs up new IP Telephony node files on the CS 1000E at the same time that it backs up the customer database.

Procedure 97

Performing a datadump using Element Manager

From within Element Manager (see Figure 93 on page 370 for details on logging in), do the following:

1Choose Services > Backup and Restore > Call Server from the navigator.

2The Call Server Backup and Restore web page opens, as shown in Figure 80 on page 223.

553-3041-210 Standard 4.00 September 2007

Page 380
Image 380
Nortel Networks 1000E warranty Performing a datadump