Installing and cross-connecting an external alarm from a PFTU Page 457 of 488

Installing an alarm through QUA6 PFTU connections

A QUA6 PFTU can be used to connect an external alarm through normally open or normally closed contacts of one of its units. The contacts operate under the same conditions as the PFTU and can support the capacities listed in Table 61.

Table 61

The AC capacities

Maximum

AC capacities

 

 

Switching power

50.0 V A

 

 

Switching voltage

125.0 V rms

 

 

Switching current

0.5 A

 

 

Figure 155 on page 458 is an example of the contacts on one unit (PFT1) of the PFTU. The figure also shows the contacts in normal operating mode, not in failure mode. Table 62 on page 458 provides the connections for all units on the PFTU.