Nortel Networks 1000E warranty Configuring a transparent rlogin port with sample data

Models: 1000E

1 490
Download 490 pages 31.09 Kb
Page 263
Image 263

Connecting a Terminal Server Page 263 of 488

9Check port configuration. Enter the command:

LIST PORT xx

LIST PORT xx ALTERNATE CHARA

Where:

xx = port number

End of Procedure

Configuring a transparent rlogin port with sample data

Sample data has been incorporated into Procedure 67. This configuration shows that a device connected to MRV Port 2 will rlogin 47.11.166.76 through pty 10.

Procedure 67

Configuring a transparent rlogin port

1Enable keepalive timer 1 for the port. Enter the command:

DEFINE PORT 2 IP TCP KEEPALIVE TIMER 1

2Enable a dedicated service using rlogin. Enter the command:

DEFINE PORT 2 RLOGIN DEDICATED SERVICE 47.11.166.76

3Enable the port to be accessible only by local command and from a serial connection only. Enter the command:

DEFINE PORT 2 ACCESS LOCAL

4Enable the In-Reach Element Manager to complete a ZMODEM transfer using the rlogin feature. Enter the command:

DEFINE PORT 2 RLOGIN TRANSPARENT MODE ENABLED

5Enable autoconnect for the port. Enter the command:

DEFINE PORT 2 AUTOCONNECT ENABLED

6Enable autodedicate for the port. Enter the command:

DEFINE PORT 2 AUTODEDICATED ENABLED