Installing software on the CS 1000E Page 147 of 488

STAT FMD

display text: Status of the specified Fixed Media

Device

command parameter: core # with values of 0 or 1

STAT RMD

display text: Status of both Removable Media Devices (RMD)

command parameter: none

STAT RMD

display text: Status of the specified Removable Media

Device

command parameter: “core #” with values of 0 or 1

At this point, it is possible to customize the HSP IP addresses on the HSP ports. To do this, change the HSP addresses on the active side, and the addresses are automatically invoked on the inactive side.

For more information, see Communication Server 1000: System Redundancy (553-3001-307).

Testing the Call Servers

Procedure 29

Testing Call Server 0

At this point in the installation, Call Server 0 is tested from active Call Server 1. Upon successful completion of these tests, call processing is switched and the same tests are performed on Call Server 1 from active Call Server 0. As a final step, call processing is then switched again to Call Server 1.