Installing software on an MG 1000T Small System Controller Page 251 of 488

3Set the time and date. Enter the command:

STAD <day> <month> <year> <hour> <minute> <second>

Where:

<day> = the day of the month (1-31).

<month> = the month number (1-12).

<year> = the year, in four-digit or two-digit form (see Note on page 251).

<hour> = the hour of the day (0-23).

<minute> = the minutes (0-59).

<second> = the seconds (0-59).

Sample entry:

STAD 2 9 2002 16 47 0

4Print the current time and date. Enter the command:

TTAD

Sample system response:

MON 02 09 2002 14 47 05

Note: Except for the year, the other entries in the time-of-day output are two-digit numbers. The year can be any year from 1901 to 2099 inclusive. It can be input as a full four-digit field or as a two-digit short form. The two-digit short form is assumed to be in the range 1976 to 2075 and the appropriate addition is made when calculating the day of week and leap years.

5Exit from LD 2. Enter the command:

****

End of Procedure

Communication Server 1000E Installation and Configuration

Page 251
Image 251
Nortel Networks 1000E warranty Ttad