Procedure 69

Connecting SDI ports on the Media Gateways

1Connect the NTBK48 3-port SDI cable to the 9-pin SDI port (RS-232) at the rear of the Media Gateways (see Figure 88).

Figure 88

SDI port access to the Media Gateway SSC card

SDI port

2Connect the system terminal to the cable marked “port 0” on the NTBK48 3-port cable. You require a Modem Eliminator adapter to connect the system to a TTY terminal. This adapter is included in the CS 1000E and the Media Gateway cable kits.

3If the system is accessed remotely, connect the system modem to the cable marked “port 1” on the NTBK48 cable.

4When instructed, connect the modem to an outside line.

5When instructed, test the modem for correct operation when the system is operating.

Note: You can use the remaining ports for other equipment, such as CDR devices or TTYs.

End of Procedure