Nortel Networks 1000E warranty Bk-Br Br-Bk Bk-S Bl-Y, Bl-W Br-W Bl-R

Models: 1000E

1 490
Download 490 pages 31.09 Kb
Page 312
Image 312

Page 312 of 488 Installing and cross-connecting a trunk card

Table 32

NT5K17 Direct Inward Dial card terminations (Part 2 of 2)

Pair

Pins

Pair color

Unit

 

 

 

 

 

39

BK-BR

 

 

14

BR-BK

 

 

 

 

 

T7

40

BK-S

 

R7

15

S-BK

7

 

 

 

 

 

41

Y-BL

 

 

16

BL-Y

 

 

 

 

 

Note: The connections on the NT5K18 Exchange Line Trunk card are polarity-sensitive. Make sure the ground side of the trunk is connected to the A leg of the NT5K18 circuit. Make sure the -50 Volt side of the trunk is connected to the B leg of the NT5K18 circuit.

Table 33

NT5K18 Exchange line trunk card cross-connect terminations (Part 1 of 2)

Pair

Pins

Pair color

Unit

 

 

 

 

T0

26

W-BL

 

R0

1

BL-W

0

 

 

 

 

 

27

W-O

 

 

2

O-W

 

 

 

 

 

T1

28

W-G

 

R1

3

G-W

1

 

 

 

 

 

29

W-BR

 

 

4

BR-W

 

 

 

 

 

T2

30

W-S

 

R2

5

S-W

2

 

 

 

 

 

31

R-BL

 

 

6

BL-R

 

 

 

 

 