Configuring a terminal and SDI ports Page 271 of 488

Controlling the baud rate

You can use a switch setting on the SSC’s faceplate to control the baud rate for port 0. Use LD 17 to configure port 1 and port 2. Make sure the baud rate and device option settings are set correctly.

Use Port 0 for software installation and upgrades. Port 0 is the only system terminal (SDI) port that you can use for software installation and upgrades.

You can use all three ports on the SSC to connect terminals or modems.

Use an NTBK48 3-port SDI cable with the SSC.

Table 19 shows the SDI port numbering.

Table 19

SDI port numbering

Port

Use

Baud rate

Data bits

Stop bits

Parity

 

 

 

 

 

 

0

MTC/SCH/BUG

Set by a DIP switch

8

1

None

 

 

 

 

 

 

1

MTC/SCH/BUG

1200

8

1

None

 

 

 

 

 

 

2

MTC/SCH/BUG

1200

8

1

None

 

 

 

 

 

 

Communication Server 1000E Installation and Configuration

Page 271
Image 271
Nortel Networks 1000E warranty Controlling the baud rate, Mtc/Sch/Bug