Page 210 of 488 Configuring the CS 1000E Call Server

TTY 13: DSBL DES: ether 2

TTY 14: DSBL DES: ether 3

3Enter the command:

****

4Perform an EDD to save your changes.

End of Procedure

Configuring Virtual Tone and Conference Circuits

Virtual Tone and Conference Circuits must be defined for use by each

MG 1000E. Use LD 17 to add Virtual Tone and Conference circuits (VXCT). Each VXCT consists of two loops. The VXCT must start with an even loop number. The Virtual Tone and Conference Circuits in the same MG 1000E must occupy contiguous double loops. For easy management, Nortel recommends to start the VXCT loops from a loop number high enough (for example, 60) to leave enough superloop number for all MG 1000E superloops. If an MG 1000E has two Virtual Tone and Conference Circuits and the starting loop is 60, VXCTs 60 and 62 must be configured.

LD 17 – Add Virtual Tone and Conference loops.

Prompt

Response

Comment

 

 

 

REQ

CHG

Change existing data

TYPE

CEQU

Common Equipment

...

...

 

VXCT

x...x

Add a Virtual Tone and Conference Circuit. Where:

 

 

x...x = 0, 2, 6, ... 158

 

 

It is recommended that Virtual Tone and Conference loops

 

 

start as a multiple of 4 and be configured as even loops

 

 

thereafter, i.e. 60, 62, 64, 66. Virtual Tone and Conference

 

 

loops in the same MG 1000E must occupy adjacent double

 

 

loops.

 

 

 

553-3041-210 Standard 4.00 September 2007

Page 210
Image 210
Nortel Networks 1000E Configuring Virtual Tone and Conference Circuits, Prompt Response Comment, Req Chg, Type Cequ, Vxct