Page 452 of 488 Installing and cross-connecting a Power Fail Transfer Unit

Table 58

Power Fail Transfer Unit connections (Part 3 of 3)

QUA6 J1 Cable

Function

Pair

Color

Connects to:

 

 

 

 

 

21T

V-BL

Telephone

 

21R

BL-V

 

 

 

 

 

 

22T

V-O

Telephone Line card

 

22R

O-V

 

PFT 5

 

 

 

23T

V-G

Central Office Trunk

 

23R

G-V

 

 

 

 

 

 

24T

V-BR

Trunk Line card

 

24R

BR-V

 

 

 

 

 

End of Procedure

Connecting a trunk to a PFTU

Follow Procedure 117 to connect a Trunk to a PFTU.

Procedure 117

Connecting a Trunk to a PFTU

1Locate the PFTU terminal blocks at the cross-connect terminal.

2Cross-connect the first pair of the assigned PFTU to the telephone. See Table 59 on page 453 for PFTU connections.

3Cross-connect the second pair of the PFTU to the TN assigned to the telephone.

4Cross-connect the third pair of the PFTU to the Central Office trunk.

5Cross-connect the third pair of the PFTU to the TN assigned to the trunk.

553-3041-210 Standard 4.00 September 2007