Page 354 of 488 Installing the Main Distribution Frame

Terminal block requirements

The cross-connect terminal requires enough connecting blocks to terminate up to four 25 pair cables for each Media Gateway and each Media Gateway Expander. When Ethernet connections are used instead of traditional cabling, the Media Card Input/Output adapter is used:

For the 1.5 Mbit DTI/PRI circuit card NTRB21, use the NTBK04 cable.

For the 2.0 Mbit DTI circuit card NTAK10, 2.0 Mbit PRI circuit card NTAK79, and 2.0 Mbit PRI circuit card NTBK50, use the NTBK05 cable.

Each IPE card slot equipped with a Line or Trunk card requires a 25-pair cable from the host Media Gateway or Media Gateway Expander.

Four conductors for the AUX cable from the Media Gateway.

One 25-pair cable from each Power Fail Transfer Unit (PFTU) QUA6.

Wiring from telephones and trunks

DANGER

Do not install telephone wiring during a lightning storm. Never touch uninsulated telephone wiring, unless the line is disconnected at the network interface.

Installing a BIX cross-connect terminal

Procedure 89 describes how to install a BIX cross-connect terminal. For detailed information, refer to the Nordex BIX documentation.

Procedure 89

Installing a BIX cross-connect terminal

1Refer to the equipment layout plan to determine where to place the cross-connect terminal.

2Lay out the terminal blocks as shown in Figure 122 on page 355.

553-3041-210 Standard 4.00 September 2007

Page 354
Image 354