Nortel Networks 1000E warranty Configuring a Terminal Server, Dcd Dtr Dsr Rxd

Models: 1000E

1 490
Download 490 pages 31.09 Kb
Page 255
Image 255

Connecting a Terminal Server Page 255 of 488

Procedure 65: "Accessing a CS 1000E from a PC through telnet Terminal Server" on page 259

Procedure 66: "Configuring a transparent rlogin port" on page 260

Procedure 68: "Accessing an MRV Console Port through the on-board modem" on page 264

Configuring a Terminal Server

Follow Procedure 62 to connect a Terminal Server with a CS 1000E system. Table 14 lists the MRV cables required to install the IR-8020M-101 Terminal Server in a CS 1000E system.

Table 14

Required MRV serial cables and connectors

Order CodeDescription

NTDU6302

Connects MRV Terminal Server to any

 

standard DTE port or DCE port when a Null

 

modem is used

NTDU6303

Used for telnet, rlogin connections

P/N-151-3028

Male RJ-45 to Male RJ-45 with connectors,

 

10 feet

P/N-350-0308

Female RJ-45 to Female DB9

Customer-made cables with the following pin out (as NTDU6302) can also be used. See Table 15.

Table 15

Customer made cable pin out

Pins on DB9 Female

 

Pins on RJ45 Male (MRV Terminal Server)

 

 

 

 

1

DCD

2

DTR

6

DSR

 

 

2

RXD

3

TxD

 

 

 

 

Communication Server 1000E Installation and Configuration

Page 255
Image 255
Nortel Networks 1000E warranty Configuring a Terminal Server, Dcd Dtr Dsr Rxd