CDV Series Direct Vent Gas Fireplace

Logs

The 36CDV logs are shipped in place. If a log is bro- ken, refer to the replacement parts list for a replace- ment. Figure 58 shows where the logs are secured to the fireplace.

The log rear is secured to the back of the fireplace.

The log front is se- cured to the bottom

of the fireplace.

Log Rear

Log Front

Ceramic

Hearth

Ember

LG441

Fig. 58 36CDV logs.

Flame Characteristics

 

Flame & Temperature Adjustment

It is important to periodically perform a visual check

 

RN/RP & EN/EP Models

 

of the pilot and burner flames. Compare them to the

For units equipped with “HI/LO” valves the flame

illustrations. (Figs. 60 & 61)

If the flame patterns appear abnormal contact a

adjustment is accomplished by rotating the “HI/LO”

adjustment knob located near the center of the gas

qualified service provider for service and adjustment.

control valve. (Figs. 59)

 

 

Turn

SIT 820 Valve

 

 

 

Turn clockwise

SIT RN/RP

counterclockwise

 

H

 

 

I

 

 

to increase

L

to decrease

 

O

flame height

 

flame height

 

 

Fig. 59 Flame adjustment knob for SIT valve.

FP1541

Fig. 60 Correct pilot flame appearance.

 

 

 

 

 

 

Yellow Flame

 

Red Glow,

 

 

 

Yellow Tips

 

 

LG442

Fig. 61 36CDV burner flame appearance.

20010175

29

Page 29
Image 29
Vermont Casting 36CDVRRN, 36CDVTRN Logs, Flame Characteristics, Flame & Temperature Adjustment, RN/RP & EN/EP Models