Fuel Conversion Instructions

CDV Series Direct Vent Gas Fireplace

A

E

The conversion of this appliance from one gas to another must be carried out by an authorized service provider.

1.

Disconnect power to the unit and shut off the gas sup-

 

ply.

2.

Remove window frame assembly.

3.

Carefully remove the logs & lava rock material.

4.

Remove the screws that are holding the burner hous-

 

ing in place.

5.

Remove the burner housing assembly. Depending on

 

the model of the appliance you may have to loosen

 

the pilot bracket retaining screw/nut to allow the pilot

 

and bracket assembly to tilt and give enough clear-

 

ance to remove the burner housing assembly.

B

C

 

OFF

 

P

 

I

O

TO

 

OFF

 

P

 

I

O

OT

F

D

FC107/108

6. Remove the main burner orifice and replace it with the

orifice supplied in the conversion kit.

7. SIT top Convertible Pilot

Gently lift off the pilot hood from the pilot. (Do not re-

move the spring clip holding the hood in place). Using

a 5/32” Allen key, unscrew the exposed orifice. Insert

the new orifice supplied in the kit, do not over tighten

the orifice. Replace the pilot hood ensuring the index

tab aligns with the notch on the hood.

8. SIT 820 NOVA Gas Control Valve (Fig. 62)

a. Using a Torx T20 or slotted screwdriver, remove

and save the three pressure regulator mounting

screws (A), pressure regulator tower (B) and

diaphram (C).

b. Ensure the rubber gasket (D) is properly positioned

and install the new HI/LO pressure regulator to the

valve using the new screws (E) supplied with the

kit. Tighten screws securely. (Reference torque - 25

in.LB)

c. Install the enclosed identification label (F) to the

valve body where it can be easily seen.

9. Reassemble the fireplace in the reverse order, except

for the window frame assembly. Leave this off until

after the unit has been checked for leaks and the gas

supply has been bled.

10. After bleeding the gas line and checking for leaks with

a soap solution, replace the window frame assembly.

Fire up the unit, check for flame impingement on the

logs, adjusting them if necessary. Check the manifold

and supply pressures against the appliance specifica-

tions.

Fig. 62 Nova SIT820 Gas Valve.

The procedure for converting from one gas to another is the same regardless of the initial gas used. The only variation is in the orifice sizes and component part numbers. Your authorized service provider will ensure the correct parts are used.

20010175

33

Page 33
Image 33
Vermont Casting 36CDVRRN Fuel Conversion Instructions, SIT top Convertible Pilot, SIT 820 Nova Gas Control Valve Fig