Vermont Casting 2823, 820 Venting System Assembly - Direct Vent, General Information, 20002191

Models: 2823 2825 820 2827 2828 2822

1 36
Download 36 pages 18.46 Kb
Page 14
Image 14
Venting System Assembly - Direct Vent

Vermont Castings Jefferson Direct Vent/Natural Vent Gas Heater

3.Attach the fan to the rear shroud by engaging the upper flange of the fan skirt under the lower edge of the shroud and secure the skirt with the four screws and one star washer provided. (Fig. 14)

4.The rheostat control switch attaches to the left side of the valve bracket at the front of the stove.

Remove the plug from the rheostat bracket.

Insert the switch box shaft through the hole in the back of the right side of the valve bracket, aligning the locator pin with the smaller hole in that bracket.

Attach the retaining nut to the switch control shaft to secure it to the plate.

Attach the Control Knob to the rheostat shaft.

Use the wire tie to secure the fan and rheostat wire harnesses together.

Upper

Flange

to

Control

Valve

ST240

Fig. 19 The upper flange of the fan skirt should be located behind the lower edge of the shroud.

ST241

Fig. 20 Correct position of fan skirt installation.

Venting System Assembly - Direct Vent

General Information

The Jefferson is approved for installation only with the vent components listed on Page 12. Follow the vent component instructions exactly.

For U.S. installations: The venting system must conform with local codes and/or the current National Fuel Gas Code, ANSI Z223.1

For Canadian installations: The venting system must conform to the current CSA B149.1 installation code.

Install the Vent Adapter Pipe

(CFM Vent Components)

1.Install the Restrictor Plate. Consult the ÔVent Run SpecificationsÕ on page 8 to determine whether the restrictor plate is needed. If so, put the restrictor plate in place within the inner flue collar as shown in Figure 16. NOTE: The restrictor plate supplied with the vertical termination should be discarded. Install restrictor plate supplied with the stove directly at stove outlet.

ST210

Fig. 16 Install the restrictor plate only if required for the venting configuration. Refer to page 8.

2.Attach Inner Starter Pipe, (found in with the logset), to the next section of inner pipe.

Run a bead of sealant about 1/2Ó from the upper end of the Inner starter pipe and join the two sec- tions together.

Drill three pilot holes into the Inner Starter and secure the assembly with three sheet metal screws. (Fig. 17)

3.Dry fit the Inner pipe assembly to the stove and determine the required vent length.

Insert the vent assembly into the flue collar, but do not attach. Measure to determine the correct length required for your installation and cut the upper end of the pipe as necessary.

Dry fit the outer vent section and cut to match the height of the Inner assembly.

14

20002191

Page 14
Image 14
Vermont Casting 2823 Venting System Assembly - Direct Vent, General Information, Install the Vent Adapter Pipe, 20002191