Vermont Castings Jefferson Direct Vent/Natural Vent Gas Heater
Wiring Diagrams
OFF ON
On/Off Switch
Wiring
|
|
|
|
| Black | Thermopile |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
TP/TH |
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| ||
TP |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |||
TH |
|
|
| Black | ||||||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
FAN
POWER
CORD
WHT BLKBLK
Chassis | GRN |
|
Ground |
| |
|
| |
| K |
|
| L |
|
| B | BLK |
|
|
Optional Thermostat Wiring
BlackTP/TH
TP
TH
(Optional)
opile Therm
Black
FAN JUNCTION BO X
Strain Relief |
ON / OFF |
Rheostat |
Snapstat |
Fig. 61 Jefferson on/off switch and optional thermostat circuit.
NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED WITH THE APPLIANCE, MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE
Draft Hood
Vent Safety Switch
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TH | Gas |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| TP | |
|
|
|
|
|
|
|
|
|
| Valve | |
|
|
|
|
|
|
|
|
|
| TH | |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| TP |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| WHT |
|
| L | K |
| B | BLK | |
|
| ||
|
|
| GRN |
Chassis Ground RHEOSTAT / SNAPSTAT | |||
|
|
| BOX |
|
|
| ST153 |
MOTOR |
| Schematic Diagram | |
|
| ||
BLK | BLK |
| BLK |
|
|
| |
|
|
| SNAPSTAT |
| BLK |
| WHT |
WHT | GRN |
| ON/OFF |
| RHEOSTAT |
ST234
Fig. 65 Jefferson fan circuit.
Fig. 64 Draft Hood Adapter wiring.
32 | 20002191 |