Vermont Castings, Majestic Products RHE Natural Vent Insert
Operation of this fireplace when not connected to a properly installed and maintained venting system or tampering with the vent safety shutoff system can result in carbon monoxide (CO) poisoning and possibly death.
Fan Kit
115 Volt, 60 Hz. 56W
The fan kit includes the following: fan, temperature sensor, speed control and a 6 ft. cord. The following explains how to start and set the fan for automatic operation.
1.Plug in the electrical cord.
2.Start gas fire - see lighting procedures.
3.Turn on fan speed control.
4.Wait until the unit has warmed up sufficiently to activate the temperature sensor.
5.Once fan starts, adjust speed control to desired fan speed. The fan will now automatically come on every time the fireplace is in operation. Should the fan not be needed simply turn off the speed control.
Stud
Thermal Sensor is | Fan is installed | ||||||||||||
attached to burner | |||||||||||||
at the back of | |||||||||||||
base | |||||||||||||
the air intake | |||||||||||||
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
| box | ||||||
|
|
|
|
|
|
| |||||||
|
|
| Stud |
| Valve |
| |||||||
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Fan Speed Control/Junction Box
| FP1252 |
Fig. 13 | Fan location. |
| Fan |
| Temperature Sensor |
Speed | |
Control | |
Black |
|
White |
|
Ground |
|
| FP394 |
Fig. 14 | Wiring diagram RN/RP. |
The appliance, when installed must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code.
For U.S.A. installations, follow local codes and the national electrical code, ANSI/NFPA No. 70.
Should this fan require servicing, the power supply must be disconnected. For rewiring of any replacement compo- nents refer to Figures 13 & 14.
Fan Removal Instructions
1.Turn off gas and electricity.
2.Remove the front glass.
3.Remove the logs.
4.Remove burner assembly and rear log support plate.
5.Remove the fan mounting nuts (2). (Fig. 13)
6.Slip off the electrical connector at the motor.
7.Lift out the fan.
8.To reinstall, reverse procedure.
10 | 10000836 |