Vermont Castings, Majestic Products RHE Natural Vent Insert
| TH |
| TP |
| TPTH |
| FP1218a |
Fig. 8b | ON/OFF switch wiring. |
If a remote wall switch is required for this fireplace installation, do not wire wall switch to 120V power supply.
Venting Instructions
Canadian Installations:
The venting system must be installed in accordance with the current
U.S.A. Installations:
The venting system must be installed in accordance with the current National Fuel Gas Code, ANSI Z223.1.
Minimum clearances to combustible materials is 1" (25mm) for B Vent (use of single wall vent is not allowed).
As with any natural draft appliances, the vent cap must always extend a minimum of 2' (610mm) above any structure within a 10' (3m) horizontal plane. (Fig. 9)
| 0 To 10’ |
|
|
| 2’ Min. | 0 To 10’ |
|
| 3’ |
| |
| Min. | (3m) |
|
|
| 2’ | 3’ |
|
| (610mm) | |
|
| Min. | (914mm) |
|
|
| Min. |
| Reference |
|
|
| Point |
|
|
|
|
| AC246a |
Fig. 9 | Example of the 2', 3', 10' rule. |
|
A minimum 12' (3.7m) vent height is required to effectively vent this fireplace.
Venting and Installation
Installer must attach red warning plate with screws supplied with the gas fire- place insert to the inside of the firebox of the fireplace into which the gas fireplace insert is installed.
WARNING
This fireplace has been converted for use with gas only and cannot be used for burning wood or solid fuels unless all original parts have been replaced and the fireplace has been
Cutting any sheet metal parts of the fireplace, in which the gas fireplace insert is to be installed, is prohibited.
If the
Ensure there are no obstructions to side air passages of decorative trim once installed on insert.
WARNING
Some factory built fireplaces have air passages on face of fireplace for zero clearance capabili- ties. All trim kits are designed so as to allow airflow to these passages. Under no circum- stances should these passages be blocked.
1.The Majestic gas inserts are designed for recessed installations into solid fuel Masonry or Factory Built Noncombustible fireplaces that have been installed in accordance with the National, Provincial, State and local building codes.
2.Measure for minimum fireplace opening requirement on Page 4 of this installation manual. (If firebrick [refractory] is removed from a factory built fireplace in order to gain minimum gas fireplace insert opening requirements, a minimum of 1/4" (6.4mm) air space is required between the gas insert fireplace's outer casing and the inner wall of the factory built fireplace).
3.To assure top performance, safety and efficiency, all inserts must be installed with an approved 4" diameter flue liner, with exception of RHE25, which should be installed with an approved 3" liner,as per
8 | 10000836 |