Vidikron Vision 15ET/CineWideTM 2. Typical PLUGE Pattern for Adjusting Brightness

Models: Vision 15ET/CineWideTM Vision 15ET Vision 15

1 82
Download 82 pages 23.77 Kb
Page 52
Image 52
Figure 4-2. Typical PLUGE Pattern for Adjusting Brightness

Operation

Brightness: On your external test pattern source, select a PLUGE pattern. (PLUGE is an acronym for “Picture Line-Up Generation Equipment.”) Figure 4-2shows a typical PLUGE pattern.

Below Black Figure 4-3. Typical Gray Bar Pattern for Adjusting Contrast

Above Black

Figure 4-2. Typical PLUGE Pattern for Adjusting Brightness

PLUGE patterns vary but generally consist of some combination of black, white and gray areas against a black background. The example above includes two vertical bars and four shaded boxes.

Select Brightness from the Picture Adjust menu and press ENTER. Adjust the level so that:

The darkest black bars disappear into the background.

The dark gray areas are barely visible.

The lighter gray areas are clearly visible.

The white areas are a comfortable level of true white.

The image contains only black, gray and white (no color).

Contrast: On your external test pattern source, select a stepped, gray-bar pattern like the one shown in Figure 4-3.

Figure 4-3. Typical Gray Bar Pattern for Adjusting Contrast

Select Contrast from the Picture Adjust menu and press ENTER. Adjust the contrast to a point just below which the white rectangle starts to increase in size.