Vidikron Vision 15ET 6Serial Communications, Serial Command Syntax, 1. Serial Commands

Models: Vision 15ET/CineWideTM Vision 15ET Vision 15

1 82
Download 82 pages 23.77 Kb
Page 73
Image 73
6Serial Communications

6Serial Communications

To interface the Vision 15 with a home theater automation/control system or a PC running terminal emulation software, connect it to your control system or PC as shown in Figure 3-13.

Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop bit and no flow control. Set the baud rate to 9600, to match that of the Vision 15 RS-232 port.

Table 6-1lists the RS-232 command set. All commands are in ASCII format and must be in

UPPERCASE.

6.1

RS-232 Connection and Port Configuration

6.2

Serial Command Syntax

When you send a valid command, the Vision 15 executes it and acknowledges it with the first three characters of the command followed by “OK;” for example, “RRAOK.“ When you send an invalid command, the Vision 15 ignores it and returns the first three characters of the command followed by “NG;” for example, “RRXNG.“

Table 6-1. Serial Commands

Command

Description

 

Reply

 

 

 

 

RRA00

Saves current settings to the CUSTOM memory

 

RRAOK

 

(Note 1)

 

 

 

 

 

RRA01

Saves current settings to the ISF Day memory (Note 1)

RRAOK

 

 

 

 

RRA02

Saves current settings to the ISF Night memory

 

RRAOK

 

(Note 1)

 

 

 

 

 

 

RRB00

Recalls the Custom memory settings

 

RRBOK

 

 

 

 

RRB01

Recalls the ISF Day memory settings

 

RRBOK

 

 

 

 

RRB02

Recalls the ISF Night settings

 

RRBOK

 

 

 

 

RRC00

Selects the S-VIDEO input

 

RRCOK

 

 

 

 

RRC01

Selects the COMPOSITE VIDEO input

 

RRCOK

 

 

 

 

RRC02

Selects the COMPONENT input

 

RRCOK

 

 

 

 

RRC03

Selects the DVI-D input

 

RRCOK

 

 

 

 

RRC04

Selects the HDMI input

 

RRCOK

 

 

 

 

RRC05

Selects the DVI-A input

 

RRCOK

 

 

 

 

RRD00

Selects the 16:9 aspect ratio

 

RRDOK

 

 

 

 

RRD01

Selects the 4:3 aspect ratio

 

RRDOK

 

 

 

 

Notes:

 

 

 

1. All image quality settings must be made with the remote control. After the image adjustments are

complete, you can use these commands to store the settings in the selected memory.

2. The power on command (PON) will not provide an OK reply; it will instead reply with a random character.

For your automation system, simply ensure that you receive a character after the PON command. If you

do not get any reply after PON, send PON again.

 

 

 

 

 

 

Vidikron Vision Model 15 Installation/Operation Manual

59

 

Page 73
Image 73
Vidikron Vision 15ET 6Serial Communications, Serial Command Syntax, RS-232 Connection and Port Configuration