Installing the Optional CineWide Lens Base Plate

Installation

Other Considerations Other considerations and tips that can help improve your installation:

Keep the ambient temperature constant and below 35°C (95°F). Keep the projector away from heating and/or air conditioning vents. Changes in temperature may cause drifts in the projector circuitry, which may affect performance.

Keep the projector away from devices that radiate electromagnetic energy such as motors and transformers. Common sources of these include slide projectors, speakers, power amplifiers and elevators.

3.4

Installing the Optional CineWide Lens Base Plate

If you are installing a Vision 15ET/CineWide, proceed as follows to install the CineWide anamorphic lens base plate. Otherwise, skip this step and proceed with Mounting the Vision

15(page 22).

1. Do not install the CineWide lens yet, only the fixed CineWide base

Note plate. You will install the CineWide lens after you install the projector and adjust the primary lens.

2.Some components shipped with your projector may differ slightly from what is shown in these instructions.

To install the fixed CineWide base plate on a Vision 15ET/CineWide:

1.Place the projector upside down on a blanket or other soft surface.

2.Line up the three mounting holes on the CineWide base plate with those on the bottom of the projector.

3.If you are mounting the Vision 15ET/CineWide on a ceiling: Line up the three holes on the projector ceiling mounting plate (included with the projector ceiling mount kit) with those on the bottom of the projector.

4.Secure the CineWide base plate (and ceiling mounting plate, if needed) to the projector with the M4x14mm screws provided with the CineWide lens base plate. See Figure 3-7.

Caution

1. Do not use the mounting screws provided with the ceiling mount

kit. Use only the hardware provided with the CineWide lens base plate.

 

2. DO NOT OVER-TIGHTEN THE SCREWS.