Central control unit CC-20:
This unit is comprised of a CPU that processes the exchange procedures, a speech link consisting of a
voice switch circuit and a signal tone generating circuit, and a power circuit.
Line modem unit LM-20:
This unit is comprised of a circuit for sending out signals from the station to the speech path, a circuit to transmit signals from the speech link to the station, a receiver and a scanning circuit for dial data, and a terminal block. Wires from the station are connected directly to the terminal block on the LM unit. A maximum of 4 stations can be connected per LM unit, and up to 4 LM units can be mounted in the
BGM unit BI-20:
This unit is comprised of a circuit to send out signals from BGM equipment, and alarm or time signals to the LM unit, a circuit that transmits control signals from the alarm or timer to the CPU, and a terminal block. The Bl unit is mounted in the exchange from the bay solely intended for this unit.
Remote control unit RC-20:
This unit is formed from relays for door remote control, power remote control and PTT control, a circuit to
activate these relays, and a terminal block. It is possible to use any bay for "option" unit to mount the
Pager control unit PC20:
This unit has the control output to remotely operate the
Speech message unit SM-20:
This unit includes a circuit to convert audio signals into digital signals, a memory storing the converted
signals, and a circuit that converts digital signals into audio signals. A single SM unit has a memory
covering 4 stations, and a control circuit. A maximum of 5 SM units can be mounted in the
Tie-line unit TI-20:
This unit is comprised of DTMF transmitting and receiving circuits for exchanging dial data with the other exchange, and a circuit for transmitting voice signals.
Power transformer unit PU-200:
This unit supplies power to the
exchanges.
Extension cabinet FC-210:
This unit is employed when a system has more than 16 stations or a number of "option" units are used. A maximum of 4
– 3 –