No

Noise encountered during

 

conversation?

 

Yes

 

Check power supply of the

 

exchange

 

 

Check wiring

between the

 

exchange and

external

 

equipment (BGM, timer)

Check wiring between EX-200 and FC-210

Replace CC

(2)Noise is heard from the station

Yes

All

stations?

 

 

 

No

 

 

Noise encountered during

No

conversation?

 

 

 

Yes

 

 

Wired in a proper

pair?

No

 

 

Yes

 

 

Cable contains any computers

Yes

data lines?

 

 

 

 

No

 

 

Replace

station

LM

 

(3) No conversation can be heard

No

All stations?

Yes

Replace CC

(4)

Paging is impossible.

No

Did you make proper No.24 programming

Yes

Make No. 24 programming

Check wiring between the exchange and station

Wire in a proper pair

Separate from computers data lines

Replace station

LM

Replace LM CC

(5) Other troubles

Additional functions cannot be operated.

Wrong wiring. Wrong DIP switch settings. Error in No. 24 programming.

Selectable functions cannot be operated.

Error in No. 24 programming.

– 40 –

Page 41
Image 41
ViewSonic EXES-2000 manual Noise is heard from the station, Replace station