4-3 Installing FC-210 extension cabinet

Follow the procedures below to install the FC-210 cabinet:

Unscrew screws that hold the top case to a chassis at 4 places in the sides of a cabinet.

Insert attached brackets (2 pieces) into bracket

Fit bracket receptacles of the FC-210 into the

receptacles on the bottom case of the EX-200.

brackets.

 

Fix the cabinet on the wall through fixing holes

 

provided on its bottom case.

(EX-200)

Connect the connector CN-5 on the CC-20 card

 

mounted in the EX-200 to the connector CN-4 on the

 

printed circuit board of the FC-210 using the

 

attached GND connector.

 

Remove a rubber membrane of 2 bushings on the

 

bottom case of the EX-200 and FC-210 to allow the

 

cable entry.

Bracket

Bracket

Knock-out hole (for wiring)

(FC-210)

Note

(1)Since the YR-820 and YR-821 cables are to be used for connecting the FC-210 to the EX-200 exchange, there is a limit to spacing between the two units. You should allow for this limit and fix them according to dimensions shown at right when they are mounted on the wall.

(2)Allow for sufficient spacing for screwing and un-

screwing the top cover when mounting on the wall.

Knock-out hole (for wiring)

Dimensions

 

 

– 6 –