Chapter 5 Programming Considerations
© National Instruments Corporation 5-25 VXI-MXI User Manual
Table 5-4. Example VXIbus/MXIbus System Required A16 Space
Amount of A16
Device Space Required
VXIbus Mainframe #1 16 KB
MXIbus Device A 512 B
MXIbus Device B 0 B
VXIbus Mainframe #2 0 B
VXIbus Mainframe #3 4 KB
VXIbus Mainframe #4 2 KB
VXIbus Mainframe #5 1 KB
VXIbus Mainframe #6 2 KB
BFFF-B000
AFFF-A000
9FFF-9000
8FFF-8000
7FFF-7000
6
FFF-
6000
5FFF-5000
4FFF-4000
3FFF-3000
2FFF-2000
1FFF-1000
0FFF-0000
F
0
E0 C0 B0 A
0
D0 90 80 50 40 006070 30 2
0
10
VXIbus Mainframe #1
MXIbus #1
VXIbus Mainframe #6
VXIbus Mainframe #3
VXIbus Mainframe #4
VXIb
us
M
a
i
n
f
rame
#5
MXIbus Device A
Figure 5-14. Example A16 Space Address Map