Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in per- sonal injury and/or property damage! Retain instructions for future reference.

Jet Pump Water Systems

See Warranty on page 12 for important information about commercial use of this product.

Description

Jet pumps are single stage domestic water pumps designed for pumping potable water in applications where the water is as much as 100 feet under ground (deep well pump). A pressure switch is a standard feature. Deep well pumps can be mounted to either a precharged, conventional type or free standing pressure tank.

Unpacking

After unpacking the jet pump, carefully inspect for any damage that may have occurred during transit. Check for loose, missing or damaged parts.

Safety Guidelines

This manual contains information that is very important to know and under- stand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.

Danger indicates an imminently haz-

ardous situation which, if not avoided, will result in death or serious injury.

Warning indicates a potentially haz- ardous situation which, if not avoided,

could result in death or serious injury.

Caution indicates a potentially haz-

ardous situation which, if not avoided, may result in minor or moderate injury.

Notice indicates important informa-

tion, that if not followed, may cause damage to equipment.

General Safety

Information

1.Read the instruction manual included with the product carefully. Be thor- oughly familiar with the controls and the proper use of the equipment.

2.Know the pump application, limita- tions and potential hazards.

Do not use to pump flammable or explo-

sive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in explosive atmospheres. Pump should only be used with liquids compatible with pump com- ponent materials. Failure to follow this warning can result in personal injury and/or property damage.

Disconnect power and release all pres-

sure from the system before attempting to install, service, relocate or perform any maintenance. Lock the power disconnect in the open position. Tag the power dis- connect to prevent unexpected applica- tion of power.

Install a screen around the inlet

pipe to prevent entrapment of swimmers.

3.Drain all liquids from the system before servicing.

4.Secure the discharge line before starting the pump. An unsecured dis- charge line will whip and possibly cause personal injury and/or property damage.

5.Check hoses for weak or worn condi- tion before each use. Make certain all connections are secure.

6.Periodically inspect pump and system components. Perform routine main- tenance as required (See Maintenance).

7.Personal Safety:

a.Wear safety glasses at all times when working with pumps.

b.Keep work area clean, unclut- tered and properly lighted -

replace all unused tools and equipment.

c.Keep visitors at a safe distance from work area.

d.Make the workshop child proof: use padlocks, master switches and remove starter keys.

8.Do not pump chemicals or corrosive liquids. Pumping these liquids shortens the life of the pumps seals and moving parts and will void the warranty.

9.When installing pump, cover the well to prevent foreign matter from falling into well, contaminat- ing the water and damaging inter- nal mechanical pumping compo- nents.

10.Always test the water from the well for purity before use. Check with local health department for test procedure.

11.Complete pump and piping system MUST be protected against below freezing temperature. Freezing temperatures could cause severe damage and void the warranty.

12.Do not run the pump dry or damage will occur and will void warranty.

Risk of electrical shock. This pump is

designed for indoor installation only.

All wiring should be performed by a

licensed or certified electrician.

13.For maximum safety, the unit should be connected to a grounded circuit equipped with a ground fault interrupter device.

14.Before installing the pump, have the electrical outlet checked by a licensed or certified electrician to make sure the outlet is properly grounded.

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

© 2008 Wayne Water Systems

For parts, product & service information

340702-001 7/08

visit www.waynewatersystems.com

Page 1
Image 1
Wayne JCU50 instruction manual Description, Safety Guidelines, General Safety Information, Unpacking

JCU50 specifications

The Wayne JCU50 is an innovative fuel dispenser designed to meet the needs of modern fueling operations. As part of Wayne's comprehensive suite of fuel dispensing solutions, the JCU50 stands out due to its advanced features, reliable technology, and user-friendly design.

One of the main features of the Wayne JCU50 is its efficient architecture that allows for high throughput, minimizing wait times for customers. The dispenser is equipped with multiple product fueling capabilities, enabling it to handle various fuel types including gasoline, diesel, and even alternative fuels. This flexibility is crucial for service stations looking to adapt to shifting market demands and the growing popularity of biofuels and electrification.

The JCU50 utilizes smart technology, incorporating digital displays that are user-friendly and intuitive. These displays provide customers with essential information including price per gallon, total sale amount, and promotional messages, enhancing the customer experience. Additionally, the dispenser's interface is designed for easy interaction, reducing confusion at the pump.

Another critical characteristic of the Wayne JCU50 is its robust construction aimed at durability and longevity. The dispenser is designed to withstand harsh weather conditions and heavy usage, ensuring reliable operation across all environments. The materials used in its construction are resistant to corrosion, promoting a longer lifespan and reducing maintenance costs.

In terms of technology, the JCU50 integrates advanced payment solutions, supporting various payment methods such as credit cards, mobile payments, and loyalty programs. This feature not only enhances convenience for customers but also boosts sales opportunities for operators. Furthermore, the dispenser is equipped with state-of-the-art security measures to safeguard transactions and prevent fraudulent activities.

The Wayne JCU50 also emphasizes sustainability. With increasing regulatory pressures around emissions and environmental responsibility, the dispenser supports eco-friendly practices, making it easier for fuel retailers to comply with new regulations.

Overall, the Wayne JCU50 represents a sophisticated solution for fuel dispensers, marrying efficiency with technology and sustainability. Its myriad features and durable design make it an excellent choice for fuel retailers looking to modernize their operations while enhancing customer satisfaction and boosting sales.