PLUS LINE
A2 Water heater piping continued
Figure 5
Piping — OPTION 2
PLUS 100/110/119
(Required for Commonwealth of Massachusetts)
An expansion tank may be required on the DHW piping. See Thermal expan- sion WARNING on page 13. Failure to comply could result in severe personal injury, death or substantial property damage.
When the water supply pressure is higher than 70 psig, install a
Drain valve
PLUS 100/110/119 Option 2
Apply the following and Figure 5 to water heaters installed in Massachusetts. The drain valve is mounted in the AUX tapping on top of the water heater.
1.Insert an
2.Connect a elbow to the AUX tapping, using suitable pipe dope or tape.
3.Pipe the drain valve to the elbow, using suitable pipe dope or tape, as shown in Figure 5.
4.Pipe the T & P relief valve in the run of the brass tee, located in the domestic water outlet piping as shown in Figure 5.
5.Obtain brass tee and drain valve from local supplier.
12 | Part Number |