PLUS LINEIndirect-Fired Water Heaters – Series 3

A6 Water heater maintenance

Maintenance schedule – annual service technician

Annual service by qualified service technician to include:

Any procedures required by local codes.

Check air vent operation.

Verify system pressure. Air venting procedure may require adding water to bring system up to pressure, typically 12 psig.

Manually operate T&P relief valve at least once a year. This will release some hot water.

Before operating T&P relief valve, make sure no one is in front of or around T&P relief valve discharge piping. Hot discharge water can cause severe personal injury or substantial property damage.

6406-10

Maintenance schedule – monthly homeowner

Move operating lever to open position for a few seconds and then move it back, allowing it to snap closed. After T&P relief valve is operated, if it continues to release water, close cold water inlet to water heater immediately. Follow draining instructions, and replace T&P relief valve. If T&P relief valve weeps periodically, it may be due to thermal expansion (see “Thermal Expansion”, page 13). Do not plug T&P relief valve or discharge piping.

Plugging T&P relief valve or discharge piping can cause excessive pres- sure in water heater, resulting in severe personal injury, death or substantial property damage.

Follow instructions on circulator to oil it, if oil-lubricated.

Check valves, pipes and fittings for leaks.

Check function of field-installed controls and valves (see control manufacturer’s instruc- tions).

Review homeowner’s maintenance responsibilities and their frequencies, including any not listed in the following paragraphs.

Homeowner monthly maintenance to include:

Check air vent operation:

Automatic air vent — remove cap (see Figure 8). Briefly push in valve and release it to clean valve seat. Screw cap on completely, then unscrew one turn. If air vent does not operate, call qualified service technician.

Figure 8

A

B

 

Remove air vent cap to check operation

6406-6

Visually check valves, pipes and fittings for leaks. Call qualified service technician to repair leaks.

20

Part Number PLUS-E017-A/1206

Page 20
Image 20
Weil-McLain PLUS-E017-A/1206 manual A6 Water heater maintenance, Maintenance schedule annual service technician

PLUS-E017-A/1206 specifications

The Weil-McLain PLUS-E017-A/1206 is a high-performance heating boiler that reflects the brand's commitment to quality engineering and advanced technology. This model is renowned for its efficiency and reliability, making it a preferred choice for both residential and commercial heating applications.

One of the standout features of the PLUS-E017-A/1206 is its exceptional efficiency rating. The boiler employs advanced condensing technology, which allows it to utilize the latent heat in exhaust gases. This means it can achieve efficiency levels of over 90%, significantly reducing energy consumption and lowering utility bills. The unit also complies with stringent regulatory standards, making it an environmentally friendly heating solution.

The PLUS-E017-A/1206's compact design is another significant characteristic, allowing for easy installation even in limited spaces. It is built with durable materials that enhance its longevity and efficiency. The sleek appearance of the unit also makes it suitable for various settings, maintaining aesthetic appeal while delivering powerful heating performance.

This boiler is equipped with advanced controls and a user-friendly interface, offering precise temperature management and efficient operation. The control panel showcases a digital display, enabling easy monitoring of system performance. Additionally, it allows for integration with smart home systems, providing users with enhanced control over their heating systems remotely.

Safety features are paramount in the PLUS-E017-A/1206. It includes multiple safety mechanisms designed to prevent overheating and pressure issues, ensuring worry-free operation. These elements, combined with Weil-McLain’s reputation for durable construction, contribute to the boiler’s overall reliability.

The PLUS-E017-A/1206 is designed with ease of maintenance in mind. It features accessible components that can be easily serviced, minimizing downtime and reducing maintenance costs. With Weil-McLain’s extensive network of support, users can rely on expert assistance when needed.

Overall, the Weil-McLain PLUS-E017-A/1206 is a robust heating solution that combines efficiency, safety, and advanced technology. Its range of features makes it an excellent choice for those seeking a dependable boiler that delivers consistent performance and energy savings. Whether for a home or business, the PLUS-E017-A/1206 represents a smart investment in heating technology.