Figure 21
GOLD Plus 30/40/60/80
Plus 40/60/80
•Zoning with pumps
•Primary/secondary piping
•Place pumps at beginnings of zones. Placing them at the ends of zones could result in heating idle zones.
•Size primary circuit manifold for total flow of all zone pumps, with pressure drop of no more than 1 foot W.C.
•Locate flow/check valves as close as possible to water heater boiler side connections
— to reduce heat loss between cycles.
Wiring options:
•Figure 30, page 48 — WMCR zone controller, optional priority
•Figure 31, page 49 — Priority zone pump
•Figure 32, page 50 — Pump relays with domestic priority
•Figure 33, page 51 — Pump relays without domestic priority
Notes | 1. | This drawing is conceptual only. It shows representative piping components and layout. |
|
| |
|
| building codes. The installer is responsible for inclusion of all required safety devices, or |
|
| other miscellaneous piping hardware not shown on drawing. The installer is responsible |
|
| for proper sizing/selection of all hardware shown on this diagram. |