ELECTRIC SHOCK  HAZARD

CAUTION:

ELECTRIC SHOCK ELECTRICAL INSTALLATIONManual background HAZARD

The grounding prong of the electrical power cord is part of a system designed to protect you from injury in the event of an electrical short.

DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THE PLUG.

Ungrounded electrical equipment cause personal injury and property damage.

ELECTRICAL INSTALLATION

1.Fryer electrical diagram and troubleshooting schematic are located on the inside of the fryer door.

2.The fryer is equipped with a three-prong grounding plug

(NEMA 15-5P) for your protection against shock hazard. The fryer must be plugged directly into a properly grounded three-prong receptacle (NEMA 15-5R).

3.The installation of this fryer must conform to local codes. In the

absence of local codes, the installation of this fryer must conform with the National Electrical Code (ANSI Z223.1).

In Canada, CSA C22.2 is applicable.

4.Because the fryer draws less than 8 amps, two fryers may be plugged into the same 15 amp circuit if required.

371 301098 OpManual for WFGA-60FS Gas Fryer